LaMUX: Optimized Logic-Gate-Enabled High-Performance Microfluidic Multiplexer Design
DescriptionTo meet the increasingly complex experimental demands, the number of microvalves in flow-based microfluidic biochips has increased significantly, making it necessary to adopt multiplexers (MUXes) to actuate microvalves. However, existing MUX designs have limited coding capacities, resulting in excessive chip-to-world interface. This paper proposes a novel gate structure for modifying the current MUX architecture, along with a mixed coding strategy achieving the maximum coding capacity within the modified architecture. Additionally, a synthesis tool for the mixed-coding-based MUXes (LaMUXes) is presented. Experimental results demonstrate that the LaMUX is exceptionally efficient, substantially reducing the usage of pneumatic controllers and microvalves in MUXes.
Event Type
Research Manuscript
TimeTuesday, June 255:15pm - 5:30pm PDT
Location3010, 3rd Floor
Topics
Design
Keywords
Emerging Models of Computation